Once you have checked your underfloor heating pack, please take some time to read this guide and study the piping and wiring diagrams.
Familiarise yourself with the various components as shown in this guide and the installation of your system will be easier to understand and carry out.
Important Points
Please remember that it is very important that the pipe is laid as directed, the pipe layout is adhered to and the pipe is free from kinks.
Divide the area into two sections and lay two equal circuits.
Electrical control wiring is required, ensure that this is in place prior to finishing work is carried out.
Flow and return pipework is required.
The control motorized valve is directional, i.e., the flow must be in the direction of the arrow on the valve body.
Notes
This pack is designed to provide a heat output of up to 100w per sq m*.
Remember to allow enough pipe to connect from the room to the manifold (the packs contain a small amount of excess pipe for connections).
It is important to bend the pipe in a "light bulb" shape to avoid kinking, if anything less than 200mm centres are used.
Before installation please read the fitting, filling and commissioning instructions carefully. These are tried and tested to provide you with excellent results.